Inspection & Instrumentation Systems and Equipment
Ozone Leak Detector 200L
Keywords: ozone gas, leak inspection, dry, metal barrel
IIC developed this ozone leak detector for conducting leakage inspections
of metal barrels using a dry method. Metal barrels are usually subjected to an
immersion test or bubble leak test.
 |
Features
- Dry leak inspection method using ozone gas
- Detection characteristics equivalent to an immersion test or bubble leak
test
- Keeps the working environment clean because there is no contamination by
water or soapy water
- Low cost
The cost of necessary detection materials is low and there is no disposal cost
for waste liquid such as soapy water.
- Environmentally friendly because it uses ozone gas present in the atmosphere.
|
Detection Characteristics
 |
Test Conditions
- Differential pressurization method:
Depressurization outside the barrel
- Testing pressure: 30 kPa
- Ozone gas concentration: 250 ppm
- Hole diameter of test piece: 30, 60,100, 150 μm
- Detection performance equivalent to a bubble leak test (JIS Z2329)
|
Basic Specifications
- Detection limit: Normally 10〜50 ppb
- Dimensions: 1400×800×1100 mm
- Power supply: 100 V
- Control: PLC control
- Display/Operation: Touch panel
|
- Differential pressurization method:
Depressurization outside the barrel
- Ozone sensor: Semiconductor sensor
- Generation of ozone gas:
- Aphonic electric discharge ozone generator
- Raw material: Dry air
|
Application examples
- Metal drums
- Vessels such as fuel tanks
Options
- Customization is possible to meet your requirements.
- Automatic chuck apparatus